Tecnomed’s AFNOR-compliant medical gas outlets ensure the safe and controlled delivery of oxygen, vacuum, nitrous oxide, and anaesthetic gases used in healthcare facilities. With a compact structure and color-coded design, these outlets enable quick integration into bed head units or gas modules. Stainless steel and plastic body options make them suitable for different project requirements.

A medical gas outlet is a terminal interface component that ends the flow coming from medical gas pipelines at the point of use and allows safe connection to medical devices. AFNOR outlets follow a standard widely used in Europe. Their connection type and internal design are engineered to operate only with AFNOR-compliant equipment.
| Feature | Description |
|---|---|
| Compliance Standard | AFNOR Norm |
| Gas Types | Oxygen (O₂), Vacuum, Nitrous Oxide (N₂O), Anaesthetic Gas (MA4) |
| Working Pressure | O₂ / N₂O / MA4: 4 – 5 bar Vacuum: -0.9 bar |
| Connection Type | Dedicated AFNOR-type socket system |
| Mounting Type | Flush-mounted, panel-mounted, or pendant-compatible |
| Color Coding | Compliant with EN ISO 7396-1 and AFNOR system color coding |
| Leak Tightness Test | 100% tested after production |
| Modular Design | Replaceable internal mechanism with cartridge system |
| Body Options | Plastic body / Metal body (Stainless Steel) |
| Feature | Plastic Body (ABS Composite) | Metal Body (Stainless Steel) |
|---|---|---|
| Durability | Standard | High |
| Weight | Lightweight | Medium |
| Material | ABS Composite | Stainless Steel |



In the industry, this product is also known as:
AFNOR gas outlet, medical gas outlet, quick release AFNOR socket, AFNOR outlet socket, AFNOR terminal socket, gas terminal point, French type gas outlet, medical AFNOR outlet
An AFNOR medical gas outlet is a point-of-use medical gas outlet with a specific mechanical connection standard commonly used in France-origin systems. It works only with AFNOR-compatible equipment.
Yes. Each standard has a different connection type, socket structure, and gas module compatibility. Using the correct standard is essential to avoid confusion and safety risks.
They can be installed flush to the surface, on panels, or on pendant systems. Our technical team provides support with the required accessories.
It depends on the application area. Plastic is suitable for lighter-use areas, while stainless steel is recommended for intensive operational areas.
Yes. At least one functional and leak tightness test per year is recommended.
With Medical Gas Outlet Afnor Norm, Tecnomed provides safe and high-performance medical gas outlet solutions compliant with the French standard. Its certified structure and durable materials ensure long service life in operating theatres, intensive care units, and clinical applications. Contact us for project-specific gas type, connection, and mounting options.
👉 Contact Tecnomed for more information and project-specific solutions.
🖥️ Click for email via PC / Laptop.
📱 Click for email via mobile device.
Contact
+90 212 909 0484
Address
İkitelli Osb. Metal iş Sanayi Sitesi 19.Blok No:40 Başakşehir İSTANBUL-TÜRKİYE
E-Mail
info@tecnomed.com.tr
sales@tecnomed.com.tr
Bed Head Unit, Intensive Care Unit, Manifold System, Medical Flowmeter, Medical Gas, Medical Gas Outlet, Medical Gas Socket, Medical Gas Terminal, Medical Gas Systems, Medical Pendant, Medikal Gaz, Operating Room Pendant, Oxygen Flowmeter, Oxygen Manifold System, Oxygen Outlet, Oxygen Terminal, Suction Regulator, Surgical Pendant
Tecnomed Copyright © 2024 All rights reserved.