It is the selection of medical gas power plants equipment by calculating the capacity of the medical gas systems that the hospital will need according to its specialization, and coupling the products needed for places such as intensive care and operating rooms to medical gas power plants with medical copper pipes.
Medical gas systems cover the entire system starting from the medical gas plant in hospitals to the delivery of medical gas to the patient. The system covers the entire process starting from the medical air plant, medical vacuum plant, AGSS plant, fully automatic oxygen plant and other fully automatic gas plants such as CO2, N2O and N2 that may be needed, to the delivery of gas to the patient bedside units, intensive care units, pendants, parapets through medical copper pipes and the use of the gas needed to the patients through the gas sockets in these products.
Nurse Call System from Tecnomed product category basically provides communication and communication between Patient and Nurse. Nurse Call System can be of 2 types as wired or wireless. It consists of basic products such as main computer, IP Software System, Control units, Room Warning Lamps, Room Control Panels, Bedside Unit Button, Patient Hand Set, WC Drawstring Call Button.
These products provide communication between the patient and the nurse. It is a basic need for hospitals and should be regularly maintained and call buttons in all rooms should be kept in working condition.
In addition, desired features can be added to this system (such as television volume on/off and lighting controls).
Reports can be taken from the system and system usage status can be checked. In addition, it can be integrated with the Hospital Information Management System and can also be kept under record.
As Tecnomed, we manufacture and provide services in accordance with TS 13401 Pagers standard.
Please contact us to offer solutions according to your requests.
The equipment in the medical air handling unit must be checked daily and weekly as specified in the manufacturer’s maintenance manuals. Air leaks, oil leaks, oil leaks, oil level, belt pulley tension control if the belt is pulley driven should be monitored daily. For compressor equipment, major revisions called overhaul should be carried out on time at the time intervals determined by the manufacturer. balancing tanks should be maintained at the required periods in accordance with the pressure vessels regulation. dryer equipment and medical filters should be maintained and replaced on time.
There must be no oil in any apparatus that touches the gas socket. Gas socket lines should never be approached with oil.
Gas sockets are systems that contain a locking mechanism. Trying to disconnect the equipment from the gas socket without opening the lock mechanism may damage the socket. There are parts of the sockets that vary according to the countries and areas where they are used. These vary in thickness and in the way the socket is inserted and removed.
BS (British Standard) sockets, which have a more rounded structure, are inserted flat on the equipment in accordance with the tab on the socket. It is removed by pressing on the sides of the socket and pulling the locking mechanism out of the way.
DIN (German Standard) sockets with angular structure are installed by bringing them to the same position with the corners of the equipment. It is removed by pressing from the sides of the socket and pulling the locking mechanism out of the way.
AF (French Norm) sockets, which have a screw appearance outwards, are inserted by turning like a screw and removed back in the same way.
In Medical Air Plant maintenance, the oils of the compressors are checked. The filters in the plant are checked and the filters that are due for replacement are replaced with new ones. In Vacuum Power Plant maintenance, the oils of vacuum pumps are checked. The filters in the plant are checked and the filters that are due for replacement are replaced with new ones. Belts are checked. PLC and electrical panels are checked. Silencer filter and solenoid valve for dryers are checked. If it is a chemical dryer, silica gels are checked and replaced if it is time for replacement. Drainage systems of the tanks are checked. The leaks of the whole system should be checked to make sure that the system is working.

Contact
+90 212 909 0484
Address
İkitelli Osb. Metal iş Sanayi Sitesi 19.Blok No:40 Başakşehir İSTANBUL-TÜRKİYE
E-Mail
info@tecnomed.com.tr
sales@tecnomed.com.tr
Bed Head Unit, Intensive Care Unit, Manifold System, Medical Flowmeter, Medical Gas, Medical Gas Outlet, Medical Gas Socket, Medical Gas Terminal, Medical Gas Systems, Medical Pendant, Medikal Gaz, Operating Room Pendant, Oxygen Flowmeter, Oxygen Manifold System, Oxygen Outlet, Oxygen Terminal, Suction Regulator, Surgical Pendant